Quick guide
VBG vs ABG
A venous blood gas (VBG) is easier and less painful to take than an arterial blood gas (ABG). It is often good enough for acid–base status, but not for oxygenation.
Typical venous vs arterial differences
| Value | Venous compared with arterial | Agreement |
|---|---|---|
| pH | About 0.03–0.04 lower than arterial | Generally agrees well in stable patients |
| PCO₂ | About 4–6 mmHg higher than arterial | Wide variation; useful mainly as a screen |
| HCO₃⁻ | About 1–2 mmol/L higher than arterial | Generally agrees well |
| PO₂ | Much lower; does not reflect lung gas exchange | Cannot replace arterial PO₂ |
| Lactate | Close to arterial in most patients | Raised venous lactate is worth repeating or confirming |
Approximate, published averages for peripheral venous samples. Individual differences can be larger, especially in shock.
A VBG is often enough for
- Checking pH and bicarbonate, for example when monitoring diabetic ketoacidosis
- Electrolytes, glucose and lactate screening
- Screening for high CO₂: a normal venous PCO₂ makes arterial hypercapnia unlikely
An ABG is needed for
- Measuring oxygenation (PaO₂, P/F ratio, A–a gradient)
- Shock or poor circulation, where venous and arterial values diverge
- An exact PaCO₂, such as in ventilation decisions
- When a raised venous PCO₂ needs confirming
Always record the sample type. Interpreting a venous sample with arterial reference ranges is a common error.
Educational summary only; follow your local guidelines and clinical judgement.