Skip to content

About this edition

References & editorial policy

Educational draft · Updated 24 October 2026 · Independent clinical review pending

Scope and safety

For medical education, not diagnosis or treatment. All practice cases are synthetic. Some panels preserve supplied pH and rounded components rather than exact Henderson–Hasselbalch consistency of the printed values; affected cases disclose the numerical difference. Interpret clinical reports with the patient’s context, local laboratory intervals and local protocols. Independent clinical review is pending.

The textbook is separate from the existing clinical analyzer. Reading, quizzes, bookmarks and synthetic practice do not consume analysis credits or change clinical interpretation. Progress is stored on this browser only; clearing browser data removes it.

Source and review policy

Educational conventions are grounded in the references below. Compensation formulas are approximate and sources differ, especially for respiratory alkalosis and metabolic alkalosis. Each chapter states the convention and limitations used. Local laboratory intervals and current protocols take precedence.

The original text and synthetic cases were prepared with AI assistance. Reference checking and software tests are not independent medical review. A qualified clinician must review the manuscript, calculations, cases, answers and specimen limitations before any claim of medical review or clinical validation, and before publication approval.

Precision and rounding

Calculate with full available precision and round only for display: pH 2 decimals; workbench gap, corrected gap, Winter range and P/F 1 decimal; educational PAO₂/A–a 2 decimals. Compact prose may omit trailing zeros or show an explicitly approximate whole number. Never compare against rounded display endpoints. Supplied synthetic panels are not silently recalculated; HH checks use constants 6.1 and 0.03 with mmHg.

Printed HCO₃⁻/CO₂ 16/32 and 12/24 calculate to pH 7.32, while the supplied panels retain 7.31. Printed 21/60 calculates to 7.17, while that panel retains 7.16. These are explicitly documented supplied-panel differences, not alternate rounding of identical inputs.

Updates and corrections

Before a new educational edition is released, record the changed topic and source, rerun numerical and interaction tests and obtain clinical review for substantive medical changes. Review content at least annually and when important source guidance changes. Report concerns through product feedback without including patient information.

Selected authoritative references

  1. 1.American Thoracic Society · Interpretation of ABGs ↗
  2. 2.Approach to Patients With High Anion Gap Metabolic Acidosis: Core Curriculum 2021 · AJKD ↗
  3. 3.Disorders of Acid-Base Balance: New Perspectives · Expected compensation table ↗
  4. 4.The serum anion gap: limitations and clinical usefulness · CJASN ↗
  5. 5.Metabolic Alkalosis: A Brief Pathophysiologic Review ↗
  6. 6.NCBI Bookshelf · Alveolar Gas Equation ↗
  7. 7.NCBI Bookshelf · Alveolar–arterial Oxygen Gradient ↗
  8. 8.NCBI Bookshelf · Methemoglobinemia ↗
  9. 9.NCBI Bookshelf · Carbon Monoxide Toxicity ↗
  10. 10.Royal College of Physicians · National Early Warning Score (NEWS) 2 ↗
  11. 11.American Diabetes Association · Standards of Care in Diabetes—2024: Glycemic Goals and Hypoglycemia ↗
  12. 12.AARC Clinical Practice Guideline: Blood Gas Analysis and Hemoximetry ↗