Skip to content

The practice room

Reason through the gas.

Original synthetic cases. A hint when you need it, the reasoning before the answer.

24 synthetic cases · No patient information or analysis credits used

Synthetic practice cases

SYNTHETIC CASEBeginner

The apparently normal gas

A synthetic arterial specimen on room air; the collection details are verified.

pH 7.40 · PaCO₂ 40 mmHg · HCO₃⁻ 24 mmol/L · PaO₂ 95 mmHg

Read the related chapter →
SYNTHETIC CASEBeginner

A low pH with a low CO₂

Synthetic arterial gas in a patient with deep breathing; no cause has been supplied.

pH 7.31 · PaCO₂ 32 mmHg · HCO₃⁻ 16 mmol/L

Synthetic rounding note

Printed-input HH pH is 7.321849 (display 7.32); the supplied pH remains 7.31. At pH 7.31 and CO₂ 32, inferred bicarbonate is about 15.57, which rounds to 16.

Read the related chapter →
SYNTHETIC CASEIntermediate

Same ratio, different physiology

Two synthetic arterial panels are compared for teaching only.

Panel A: HCO₃⁻ 24, PaCO₂ 40 · Panel B: HCO₃⁻ 48, PaCO₂ 80

Read the related chapter →
SYNTHETIC CASEIntermediate

Timing changes the expectation

A synthetic PaCO₂ rise from 40 to 60 mmHg is considered first acutely, then after renal adaptation.

Baseline HCO₃⁻ 24 mmol/L · PaCO₂ 60 mmHg

Read the related chapter →
SYNTHETIC CASEBeginner

A unit trap

Synthetic arterial gas printed using kPa, while an exam formula uses mmHg.

pH 7.40 · pCO₂ 5.3 kPa · HCO₃⁻ 24 mmol/L

Read the related chapter →
SYNTHETIC CASEIntermediate

The wrong oxygen source

A synthetic capillary gas is submitted with an oxygen-delivery setting.

Capillary pO₂ 55 mmHg · FiO₂ 0.30

Read the related chapter →
SYNTHETIC CASEBeginner

An acute CO₂ rise

Synthetic arterial gas after an abrupt decrease in ventilation.

pH 7.26 · PaCO₂ 60 mmHg · HCO₃⁻ 26 mmol/L

Read the related chapter →
SYNTHETIC CASEAdvanced

Less bicarbonate than expected

Synthetic arterial gas with abrupt ventilatory deterioration and low bicarbonate.

pH 7.16 · PaCO₂ 60 mmHg · HCO₃⁻ 21 mmol/L

Synthetic rounding note

Printed-input HH pH is 7.166947 (display 7.17); the supplied panel retains 7.16. At pH 7.16 and CO₂ 60, inferred bicarbonate is about 20.67, which rounds to 21.

Read the related chapter →
SYNTHETIC CASEBeginner

An alkalemic low-CO₂ gas

Synthetic arterial panel during a brief episode of increased ventilation; the cause is not specified.

pH 7.49 · PaCO₂ 30 mmHg · HCO₃⁻ 22 mmol/L

Read the related chapter →
SYNTHETIC CASEAdvanced

Two low values, two processes

Synthetic arterial panel in systemic illness, without a confirmed diagnosis.

pH 7.40 · PaCO₂ 20 mmHg · HCO₃⁻ 12 mmol/L

Read the related chapter →
SYNTHETIC CASEIntermediate

The elevated-gap pattern

Synthetic arterial case; use a teaching gap baseline of 12 without potassium.

pH 7.31 · PaCO₂ 32 · HCO₃⁻ 16 · Na⁺ 138 · Cl⁻ 102

Synthetic rounding note

Printed-input HH pH is 7.321849 (display 7.32); the supplied pH remains 7.31. Rounded bicarbonate can explain the difference; do not overwrite supplied values.

Read the related chapter →
SYNTHETIC CASEIntermediate

Bicarbonate loss

Synthetic arterial case following gastrointestinal fluid loss; teaching baseline AG 12.

pH 7.29 · PaCO₂ 30 · HCO₃⁻ 14 · Na⁺ 140 · Cl⁻ 114

Read the related chapter →
SYNTHETIC CASEIntermediate

Alkalemia after gastric loss

Synthetic arterial case with a history of gastric losses; no treatment decisions are requested.

pH 7.50 · PaCO₂ 48 mmHg · HCO₃⁻ 36 mmol/L

Read the related chapter →
SYNTHETIC CASEAdvanced

Unexpectedly low CO₂

Synthetic arterial gas with bicarbonate elevation and marked alkalemia.

pH 7.70 · PaCO₂ 30 mmHg · HCO₃⁻ 36 mmol/L

Read the related chapter →
SYNTHETIC CASEIntermediate

A response that fits

Synthetic arterial metabolic-acidosis case.

pH 7.31 · PaCO₂ 24 mmHg · HCO₃⁻ 12 mmol/L

Synthetic rounding note

Printed-input HH pH is 7.321849 (display 7.32); the supplied pH remains 7.31. At pH 7.31 and CO₂ 24, inferred bicarbonate is about 11.68, which rounds to 12.

Read the related chapter →
SYNTHETIC CASEAdvanced

A response that fails

Synthetic arterial metabolic-acidosis case with limited ventilation.

pH 7.10 · PaCO₂ 40 mmHg · HCO₃⁻ 12 mmol/L

Read the related chapter →
SYNTHETIC CASEIntermediate

Matched gap rise and bicarbonate fall

Synthetic arterial case; normal AG 12 is supplied for the exercise.

pH 7.31 · PaCO₂ 32 · HCO₃⁻ 16 · Na⁺ 138 · Cl⁻ 102

Synthetic rounding note

Printed-input HH pH is 7.321849 (display 7.32); the supplied panel retains 7.31. Gap and compensation calculations use the supplied components, not a repaired pH.

Read the related chapter →
SYNTHETIC CASEAdvanced

A hidden gap in hypoalbuminemia

Synthetic contemporaneous chemistry and arterial gas; low albumin is measured.

pH 7.34 · PaCO₂ 38 · HCO₃⁻ 20 · Na⁺ 140 · Cl⁻ 108 · albumin 20 g/L

Read the related chapter →
SYNTHETIC CASEIntermediate

Oxygenation on supplemental oxygen

Synthetic verified arterial sample on a known stable FiO₂.

PaO₂ 80 mmHg · PaCO₂ 40 mmHg · FiO₂ 0.40

Read the related chapter →
SYNTHETIC CASEAdvanced

Estimate the A–a gradient

Synthetic arterial room-air gas at sea level; RQ 0.8 is assumed.

PaO₂ 60 mmHg · PaCO₂ 40 mmHg · FiO₂ 0.21

Read the related chapter →
SYNTHETIC CASEAdvanced

Systemic illness with normal pH

Synthetic arterial case in systemic illness; no confirmed etiology is provided.

pH 7.40 · PaCO₂ 20 · HCO₃⁻ 12 · Na⁺ 140 · Cl⁻ 104

Read the related chapter →
SYNTHETIC CASEAdvanced

A chronic context matters

Synthetic arterial gas in a patient with a documented history of sustained hypercapnia.

pH 7.35 · PaCO₂ 60 mmHg · HCO₃⁻ 32 mmol/L

Read the related chapter →
SYNTHETIC CASEIntermediate

The complete synthetic panel

Synthetic arterial values; use baseline AG 12, no potassium and room air.

pH 7.31 · PaCO₂ 32 · PaO₂ 92 · HCO₃⁻ 16 · Na⁺ 138 · Cl⁻ 102 · K⁺ 4.1 · FiO₂ 21%

Synthetic rounding note

Printed-input HH pH is 7.321849 (display 7.32); the original supplied pH 7.31 is preserved. This is not exact consistency of the printed inputs.

Read the related chapter →
SYNTHETIC CASEAdvanced

The correct answer is a limitation

Synthetic non-arterial case with oxygen delivery not recorded.

Venous pH 7.32 · venous pCO₂ 48 mmHg · venous pO₂ 35 mmHg · FiO₂ unknown

Read the related chapter →